29mm slim body
Fits shallow ceiling voids, furniture recesses and joinery where a brick-style supply cannot go.
LED Power Supplies · CP Series
The CP Series is a 29mm slim constant voltage LED power supply that dims smoothly from full output down to about 1%, and accepts five kinds of dimmer on the same unit. 12V, 24V and 48V, from 60W to 200W.
Introduction
A cove, a coffer or a shelf of linear light is usually commissioned at full brightness, in daylight, with the contractor on site. Then it lives most of its life at 10 to 30 percent: hotel corridors at night, a living room after dinner, a restaurant during service. That is where a cheap power supply gives itself away with a shimmer, a visible step, or a light that refuses to go low and then snaps off.
The CP Series is built for that end of the range. High-frequency PWM with soft start keeps output steady as it fades, and the LED can start from around 1 percent. And because the unit accepts Triac, 0-10V, 1-10V, 10V PWM and resistor control, it works with whatever dimmer the project finally lands on, in a body only 29mm high.
Control
Choose the control that suits the room. The power supply stays the same.
Models
Choose the voltage that matches your LED product, then the wattage with headroom above the connected load.
| Voltage | Power | Max current | L × W × H |
|---|---|---|---|
| 12V | 60W | 5.0 A | 145 × 48 × 29 mm |
| 12V | 100W | 8.3 A | 160 × 48 × 29 mm |
| 12V | 150W | 12.5 A | 180 × 64 × 29 mm |
| 12V | 200W | 16.7 A | 205 × 64 × 29 mm |
| 24V | 60W | 2.5 A | 145 × 48 × 29 mm |
| 24V | 100W | 4.2 A | 160 × 48 × 29 mm |
| 24V | 150W | 6.3 A | 180 × 64 × 29 mm |
| 24V | 200W | 8.3 A | 205 × 64 × 29 mm |
| 48V | 100W | 2.0 A | 160 × 49 × 29 mm |
| 48V | 150W | 3.0 A | 180 × 63 × 29 mm |
| 48V | 200W | 4.0 A | 205 × 63 × 29 mm |
Specifications
| Driver type | Constant voltage |
|---|---|
| Output voltage | 12V, 24V or 48V DC |
| Output power | 60W, 100W, 150W, 200W (48V: 100W–200W) |
| Input | AC 100–240V, 50/60Hz |
| Dimming | Triac, 0-10V, 1-10V, 10V PWM, resistor |
| Dimming range | 0–100%, LED start from about 1% |
| Height | 29mm |
| Cooling | Free-air convection, fanless |
| Protection | Overload, over-temperature, short circuit, over-voltage, auto-recovery |
| Use | Indoor, Class I / II / III installations |
Features
Fits shallow ceiling voids, furniture recesses and joinery where a brick-style supply cannot go.
Triac, 0-10V, 1-10V, 10V PWM and resistor on one unit, so the dimmer can be decided late.
High-frequency PWM and soft start: no pop-on, no shimmer, no visible flicker at low levels.
12V, 24V and 48V cover standard strip, long runs and 48V systems.
Free-air convection cooling with no moving parts, quiet in bedrooms and hotel rooms.
Overload, over-temperature, short circuit and over-voltage, with automatic restart once the fault clears.
AC 100–240V, 50/60Hz for stable operation on varying site supplies.
Four power ratings per voltage with published dimensions, so cavities can be detailed early.
Installation
A slim supply still needs service one day. Plan an access hatch or removable panel, leave air space around the body, keep it out of insulation, and route dim signal wires away from mains cabling.
Applications
Dimmable power behind recessed and surface linear profiles.
Indirect light that fades evenly along the whole run.
Wall-dimmer control, quiet and concealed.
Scene dimming from a 0-10V panel.
Indirect light set to suit daylight and screen work.
A simple wall dimmer for strip lighting in living and bedrooms.
Low, steady light through the evening service.
Slim enough for furniture voids and plinths.
Dimmable constant voltage for 12V and 24V neon flex.
FAQ
Triac (phase-cut) wall dimmers, 0-10V, 1-10V, 10V PWM and resistor (potentiometer) control are all supported on the same unit. Pick the control that suits your wall dimmer, BMS or controller.
Dimming runs from 0 to 100 percent, and the LED can start from about 1 percent. High-frequency PWM with soft start keeps the light steady at low levels, with no visible flicker.
Multiply the strip's watts per metre by the total length, then choose a supply comfortably above that load rather than at its limit. A margin of around 20% keeps the unit cooler in an enclosed cavity and extends its life.
Always match the voltage of your LED product. For new designs, 24V suits most strip runs; 12V suits short runs up to about 5 metres per feed; 48V suits very long runs or 48V-rated strip.
Every model is 29mm high. Length and width depend on wattage, from 145 × 48mm at 60W to 205 × 64mm at 200W, so check the footprint of your chosen model against the space.
No heatsink or fan is needed; it cools by free-air convection. Leave some air space around the body and do not cover it with insulation.
The supply protects itself against overload, over-temperature, short circuit and over-voltage, and restarts automatically once the fault is removed. There is no fuse to replace.
It is designed for indoor use in Class I, II and III installations. Mount it in a dry, accessible location, away from moisture and splash zones.
Send your strip type, run lengths and control method, and we will recommend the voltage and wattage.